| Last year Florida was faced with the worst hurricane season in a century, with four of the six major hurricanes directly affecting Central Florida. Charley made landfall on the southwest coast of Florida during the evening of August 13th with maximum sustained winds near 150 MPH. Charley was responsible for over 6 billion dollars in property damages ranging from total devastation, to blown off roofs, to water intrusion due to saturation.
Three weeks later, on September 5th, Frances battered Central Florida. Ivan
followed Frances making landfall on September 21st. Last but not least, Jeanne
entered near Stuart as a category three hurricane, six days later, following
the same path of Frances, three weeks earlier. Needless to say, Mother Nature
was moving into Central Florida faster than were the adjusters, roofers and
contractors hired to deal with property damage. While leaks, humidity, and
wind drafts were some of the problems Central Florida residents had to endure,
a major concern plaguing the affected dwellings was mold proliferation. One
can gauge the degree of water damage in a building by the composition of the
mold spores found inside the affected building.
There are three stages of mold
colonization, based on water activity requirements. Water activity (Aw) is
an expression of the relative water availability in a substance and it measures
the vapor pressure generated by the moisture present in a hygroscopic product.
The water activity of a product is one-hundredth its equilibrium relative humidity.
Low Aw (<0.85) favors primary colonizers such as Aspergillus versicolor, Penicillium and Wallemia. Secondary colonizers such as most Aspergillus species and Cladosporium need intermediate levels of Aw (0.85-0.90), and fungi that require wet conditions, thus high Aw (>0.90) are considered tertiary colonizers and include Alternaria, Aspergillus fumigatus, Chaetomium, Fusarium, Memnoniella, and Stachybotry, among others. This study concentrates on the proliferation of a genus associated with high water damage conditions, Stachybotrys. Figure 1. Survey of affected buildings vs. unaffected buildings. Buildings were considered affected if Stachybotrys or Memnoniella spores were identified. Air trap samples from 591 buildings were examined from July 2004 to January 2005. During that period of time, Stachybotrys and/or Memnoniella (Stachybotrys echinata) affected 226 buildings out of the 591 examined (Figure 1). Individual levels of contamination ranged from 21 spores/cubic meters to 87,900 spores/cubic meter. Monthly concentrations ranged from 1055 spores/cubic meter to 201,224 spores/cubic meter (Figure 2). Andersen agar plate impactor samples corroborated Stachybotrys proliferation, with levels ranging from 700 colony forming units (CFU's)/cubic meter to over 350,000 CFU's/cubic meter. The peak incidence was observed during the month of October where Stachybotrys affected 52.71% of the buildings examined. Total concentrations for October were 19,190 spores/cubic meter for Stachybotrys and 141,921 spores/cubic meter for Memnoniella. A gradual decrease was observed in the number of affected buildings during November (33%), December (29%) and January (31%).
However, while the number of affected buildings was decreasing, mold amplification
was on the rise. December concentrations went from approximated 161,00 to approximately
208,000 spores/cubic meter. Water intrusion due to roofless housing, water
damage due to prolonged floods, and the characteristic heat and humidity of
Florida can be factors enhancing mold amplification. Now that winter is here,
and the heat and the humidity are lower, freezing temperatures in central Florida
are forcing dwellers to use heating devices to keep warm. Once again the combination
of heat and humidity can be a cause of mold amplification, as evidenced by an increase in the number of affected buildings in January 2005 over December 2004. To compound the problem, many houses still have only a blue tarp for roofing, and these tarps are beginning to deteriorate. Rainfall associated with frontal systems continues to pound unprotected homes. We will continue to monitor Central Florida's mold problem as we approach a new season? About EMSL Analytical, Inc. EMSL Analytical, Inc. currently services 7,000 clients internationally. Those clients include IAQ professionals, environmental consultants, abatement firms, restoration firms, environmental engineers, industrial hygienists, construction firms, engineering firms, remediation firms, contractors, mortgage companies, home inspectors, building inspection firms, carpet cleaners, duct cleaners, home owners, home builders, air conditioning contractors, roofing companies, health and safety professionals, hospitals, doctors, manufacturing firms, management firms, real estate firms, landlords, mortgage companies, attorneys, testing firms, laboratories, schools, universities, forensic consultants, health departments, fortune 500 firms and state, local and federal government agencies. EMSL Analytical, Inc. currently operates 24 laboratories throughout the nation with full analytical services, including environmental microbiology (mold, bacteria, Legionella, Coliforms, indoor allergens, mycotoxins, endotoxins), DNA based polymerase chain reaction (PCR), asbestos, lead, indoor air quality, industrial hygiene, environmental chemistry, materials, forensic, failure, and mechanical testing. In addition to laboratory services, the firm provides mold management seminars, free IAQ seminars, and free sampling workshops at locations throughout the country. EMSL Analytical currently holds accreditations with the American Industrial Hygiene Association (AIHA), including the AIHA Environmental Microbiology Laboratory Accreditation Program (EMLAP), the AIHA Environmental Lead Laboratory Accreditation Program (ELLAP), the AIHA Industrial Hygiene Laboratory Accreditation Program (IHLAP), the National Voluntary Laboratory Accreditation Program (NVLAP), the New York Department of Health (NYDOH), TX DOH, CA E-LAP and various other state, federal and private accrediting bodies. The labs are also successful participants in AIHA's Proficiency Analytical Testing (PAT), Environmental Lead Proficiency Analytical Testing (ELPAT), and the Environmental Mold Proficiency Analytical Testing (EMPAT) programs. EMSL maintains a rigorous in-house QA/QC program to ensure our clients are receiving the most accurate and legally defensible results possible.